E. Air Shutter Setting
Air shutter settings may be adjusted by a qualifi ed install-
er at the time of installation. The air shutter is set at the
factory for minimum vertical vent run. Adjust air shutter for
longer vertical runs. See Figure 9.5.
• Loosen the 1/4 in. screw.
• Twist shutter to adjust.
• Shutter may be open for longer horizontal vent runs.
• Do not close the air shutter more than 1/16 in. for NG or
1/4 in. for LP.
• Tighten the screw.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 9.5 Air Shutter
Air Shutter Settings
RED60
FULL GRANITE KIT
LIGHT & MEDIA KIT
FULL PORCELAIN KIT
SHEET METAL
REFRACTORY
NG
LP
.16 in.
1/4 in.
.06 in.
1/4 in.
.16 in.
1/4 in.
.16 in.
1/4 in.
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13