B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
DECORATIVE BARRIER FRONT
(NOT SHOWN)
SECTION 4.B.
FAN KIT
SECTION 3.I
CLEAR SPACE
SECTION 3.A.
Figure 3.2 General Operating Parts
C. Fuel Specifications
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
D. Wall and Mantel Temperatures
Combustible Mantel and Surfaces around a Fireplace
The allowable temperature rise above ambient is 117 °F
(47 °C) for all exposed combustible surfaces around the
fireplace, including the mantel, when installed according
to the installation instructions. Non-combustible surfaces
and mantels do not have a maximum temperature limit;
however the installation instructions must still be followed
for any restrictions on placement of non-combustible
materials on or around the fireplace.
Example: The mantel above a fireplace in a room
that is 70 °F (21 °C) is allowed to reach but not
exceed 187°F (86 °C) (70 °F (21 °C) +117 °F (47
°C) = 187 °F (86 °C).
FIXED GLASS ASSEMBLY
AND BARRIER
(NOT SHOWN)
SECTION 4.B.
MANTEL
HEARTH
CONTROL CAVITY
SECTION 3.I
Heat & Glo • I25X-N-AU, I35X-N-AU Owner's Manual • 2547-981 Rev. B • 1/23
E. Good Faith Wall Surface/TV Guidelines
If installing a television (TV) above the appliance, see
appliance Installation Manual Section 2.B.
F. Before Lighting Appliance
Before operating this fireplace for the first time, have a
qualified service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the firebox.
• Review proper placement of logs, ember material and/
or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Verify Glass Seal Plate is properly installed. See Figure
3.4.
WARNING! Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monox-
ide exposure.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fireplace with fixed glass assembly removed.
• Verify collar slide plate screw is attached see Figure 3.3.
Figure 3.3 Collar slide plate Screw Detail
BE SURE SLIDE
PLATE SCREW IS
FULLY TIGHTENED.
9