C. Active Convection Technology
The fi replace appliance has been provided with an active
convection blower. The blower is required to keep lower
control chamber component temperatures at an ideal op-
erating temperature. The blower also provides for more
effi cient use of appliance heat by assisting the convection
air around the fi rebox and back into the room. A four inch
fl exible duct kit has been provided with the appliance. One
end of the fl ex duct will connect to the fan bracket assembly
located in the lower control chamber. See Figure 6.5, Detail
A. The other end will terminate to an interior wall of the
house. The intake grille panel provided with the appliance
must be used. See Figure 6.5 and Figure 6.6.
Note: The blower is essential for keeping components and
the appliance environment in safe operating temperatures.
Note: Refer to Section 8.B if the active convection blower
is to be moved to the right side.
WARNING! Risk of Fire! DO NOT terminate blower vent
into an attic, crawl space, or the appliance chase. Vent
must terminate on an adjacent, interior wall.
4 INCH
CONVECTION
AIR DUCT
8 FT.
MAXIMUM
MAX. OF 2
90° BENDS
Figure 6.5 Active Convection Technology Duct Venting Specifi cations.
44
8 FT.
MAXIMUM
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
H1 MAX. = 8 FT.
H1 + V1 + H2 = 8 FT.
MAX. = TWO 90° BENDS
INLET CONVECTION AIR MAY BE VENTED IN
ANY DIRECTION,INCLUDING DOWNWARD.
H1
V1
Figure 6.6. Active Convection Technology Duct and Termination.
SEE DETAIL A
(INCLUDED WITH FLEX DUCT)
4 INCH
CONVECTION
AIR DUCT
DETAIL A
24-IN. MIN.
CLEARANCE FROM
INTAKE TO
OBJECTS = 24 IN. MIN.
LOUVERED GRILLE
H2
NOTE: The 6 in. x 5.5 in.
intake grille panel provided
with the appliance must be
used.
ZIP TIE
4 INCH FLEX DUCT
FAN BRACKET ASSEMBLY