Heat & Glo RED60-NNN Owner's Manual
Hide thumbs Also See for RED60-NNN:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions regarding installation, operation or service.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner's Manual • 2159-971 Rev. F • 12/14
Owner's Manual

Care and Operation

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RED60-NNN and is the answer not in the manual?

Questions and answers

Summary of Contents for Heat & Glo RED60-NNN

  • Page 1: Care And Operation

    See Table of Contents for location of additional Commonwealth gases, unless a certifi ed kit is used. of Massachusetts requirements. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 2: Welcome

    MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 3: Table Of Contents

    C. Contact Information ......25  = Contains updated information. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 4: Limited Lifetime Warranty

    All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 5 SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 6: Product Specifi C Information

    Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 7: Important Safety And Operating Information

    • Install a switch lock or a wall/remote control with child technician to service the appliance. protection lockout feature. • Keep remote controls out of reach of children. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 8: General Operating Parts

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- erate fi replace with fi xed glass assembly removed. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 9: Lighting Instructions (Ipi)

    Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 10: Appliance Break-In

    HIGH Figure 3.3 HI/LO Knob Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 11: Detailed Component Operating Instructions

    Set the module selector switch to the OFF position. • Wait fi ve (5) minutes to allow possible accumulated gas to clear. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 12: Maintenance And Service

    5. Assure proper left and right placement of glass and engage all lower spring latches. CAUTION! Risk of Burns! The fi replace shall be turned off and cooled before servicing. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 13: Remote Control

    • Verify operation of remote. Refer to remote control operation instructions for proper calibration and setup procedure. • Place batteries as needed in remote transmitters and battery-powered receivers. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    • Verify burner is properly secured and aligned with pilot or igniter. • Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 15: Frequently Asked Questions And Troubleshooting

    “ON”. Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatnglo.com to locate a dealer. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 16: Troubleshooting - Intellifire Plus™ Ignition System

    Polish fl ame sensing rod with fi ne steel wool to remove any contaminants that may have accumulated on fl ame sensing rod. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 17: Troubleshooting - Pvi-Dvp

    REMOTE modes, system immediately valve is defective and should replaced. locks-out with 3 LED alarm. Does not spark or attempt to ignite. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 18: Reference Materials

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. See your dealer if you have questions. Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...
  • Page 19: Service Parts

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2014 Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Owner’s Manual • 2159-971 Rev. F • 12/14...

Table of Contents