Mantel And Wall Projections - Heat & Glo RED60 Installation Manual

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 10.A.
Combustible Mantels
12
11
10
9
8
7
6
9
8
7
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
Figure 10.6 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 10.A.
Non-Combustible Mantels
MAX.
16
10
9
8
7
6
3
5
2
1/2
1
4
MEASUREMENTS FROM TOP EDGE OF THE
FIRESCREEN DOOR ASSEMBLY
Figure 10.7 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
Note: All
measurements
in inches.
TO CEILING
18
43
25
13
12
11
10
Note: All
TO CEILING
measurements
in inches.
43
MIN.
12
6
5
4
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
Mantel Legs Or Wall Projections Extending
Past The Face Of The Fireplace
TOP VIEW
4 IN.
FIREPLACE
MAX.
OPENING
6 IN. MIN.
= ACCEPTABLE
NON-COMBUSTIBLE
MANTEL LEG
ZONE
Figure 10.8 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
2 IN.
MIN.
UNLIMITED
65