Sharp MX-M550U Service Manual page 69

Digital multifunctional system
Hide thumbs Also See for MX-M550U:
Table of Contents

Advertisement

6-C
Adjust the image magnification in the main
scanning direction in DSPF front-face mode
(CCD)
This adjustment is needed in the following situations:
* The CCD unit has been removed from the machine.
* The CCD unit has been replaced.
* Images are not correctly magnified in the main scanning direc-
tion.
* The MFP control PWB has been replaced.
* The EEPROM on the MFP control PWB has been replaced.
* The scan control PWB has been replaced.
* The EEPROM on the scan control PWB has been replaced.
* U2 trouble has occurred.
1)
On the DSPF original tray, place such an original as illustrated
below.
10mm
2)
Make a normal copy on A4 paper.
3)
Measure the lengths of the copied image and the original
image.
original
10
50
100
150
200
4)
Determine the image magnification factor using the following
formula:
Image magnification factor (%) = Copy dimension/original
dimension x 100
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100 0.8%),
no adjustment is required; otherwise, do the following steps.
A4 size
10mm
copy
250
10
50
100
150
200
250
MX-M700N ADJUSTMENTS 6 – 18
5)
Go through the modes specified in Simulation 48-1.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
6.CIS(MAIN)
50
7.SPF(MAIN)
Select other than 0 - 2,
and press [START] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
Select 1, and
Press [START] key.
press [START] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
Select 0, and press [START] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-16, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
6.LCC
(ABOVE+10: DUPLEX MODE)
Select 2, and press
[START] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
6)
Using the mumeric keypad, select the number that corre-
sponds to the mode for which to make adjustments.
Select the adjustment item that is intended to adjust the image
magnification in the main scanning direction in DSPF front-
face mode (CCD). (SPF (MAIN))
7)
Press the Start key.
8)
Adjust the image magnification factor by entering an appropri-
ate value through the numeric keypad.
9)
Press the P or Start key.
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat the above adjustments until an acceptable result is
obtained.
50
5.SPF(SUB)
50
50
Press [SYSTEM SETTINGS] key.
50
Press [SYSTEM SETTINGS] key,
or terminate copying.
Press [START] key, or press
[SYSTEM SETTINGS] key.
1
Press [START] key, or press
[SYSTEM SETTINGS] key.
100