SIMULATION 46-24
EXP.LEVEL SETUP SCANNER(SUPER FINE). SELECT 0-11,AND
PRESS START.
0.AUTO
50
1.1.0
50
3.3.0
50
4.4.0
50
6.AUTO(H)
50
7.1.0(H)
9.3.0(H)
50
10.4.0(H)
46-25
Purpose
Adjustment
Function (Purpose) Used to adjust the scanner exposure level
in the ultra fine text mode.
Section
Operation/Procedure
1)
Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
* Normal mode (Image density adjustment level)
* Normal mode (Image density adjustment level) (Half-tone
mode)
* Auto mode
* Auto mode (Half-tone mode)
2)
Press the [START] key.
3)
Enter the image density adjustment value with 10-key.
4)
Press [START] key or press [P] key.
The adjustment value is set.
Item
0
AUTO
Auto
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
6
AUTO (H)
Auto (Half-tone)
7
1.0 (H)
Exposure level 1
(Half-tone)
8
2.0 (H)
Exposure level 2
(Half-tone)
9
3.0 (H)
Exposure level 3
(Half-tone)
10
4.0 (H)
Exposure level 4
(Half-tone)
11
5.0 (H)
Exposure level 5
(Half-tone)
NOTE: Only the set value is changed and no printing is performed.
SIMULATION 46-25
EXP.LEVEL SETUP SCANNER(ULTRA FINE). SELECT 0-11,AND
PRESS START.
0.AUTO
50
1.1.0
50
3.3.0
50
4.4.0
50
6.AUTO(H)
50
7.1.0(H)
9.3.0(H)
50
10.4.0(H)
2.2.0
50
5.5.0
50
50
8.2.0(H)
50
50
11.5.0(H)
50
Setting
range
0 - 99
2.2.0
50
5.5.0
50
50
8.2.0(H)
50
50
11.5.0(H)
50
MX-M700N SIMULATION 7 – 44
46-27
Purpose
Function (Purpose) Used to adjust the gamma (density gradi-
1
Section
Operation/Procedure
(Scanner mode selection)
1)
Select the number corresponding to the scanner mode to be
adjusted with 10-key. (Select one of 1 - 9.)
2)
Press the [START] key.
(Gamma adjustment)
After completion of the above procedures, perform the following
procedures.
1)
Enter the gamma level with 10-key.
2)
Press the [START] key.
The greater the adjustment value is, the greater the gamma value
is, resulting in a higher contrast.
1
OC_Fine.HT
2
OC_SFine.HT
3
OC_UFine.HT
4
SPF_Fine.HT
5
SPF_SFine.HT
Default
6
SPF_UFine.HT
50
7
CIS_Fine.HT
8
CIS_SFine.HT
9
CIS_UFine.HT
SIMULATION 46-27
GAMMA SETUP(SCNNER), SELECT 1-9, AND PRESS START.
1.OC_Fine.HT
4.SPF_Fine.HT
7.CIS_Fine.HT
46-31
Purpose
Function (Purpose) Used to adjust sharpness of the copy
Section
Operation/Procedure
(Copy mode selection)
1)
Select the number corresponding to the copy mode to be
adjusted with 10-key. (Select one of 1 - 16.)
2)
Press the [START] key.
(Sharpness adjustment)
After completion of the above procedures, perform the following
procedures.
1)
Enter the sharpness level with 10-key.
2)
Press the [START] key.
The greater the adjustment value is, the greater the sharpness is.
Adjustment
ent) of the network scanner mode.
Item
Fine text (Half-tone)
(OC)
Super fine (Half-tone)
(OC)
Ultra fine (Half-tone)
(OC)
Fine text (Half-tone)
(SPF)
Super fine (Half-tone)
(SPF)
Ultra fine (Half-tone)
(SPF)
Fine text (Half-tone)
(CIS)
Super fine (Half-tone)
(CIS)
Ultra fine (Half-tone)
(CIS)
64
2.OC_SFine.HT
64
3.OC_UFine.HT
64
5.SPF_SFine.HT
64
6.SPF_UFine.HT
64
8.CIS_SFine.HT
64
9.CIS_UFine.HT
Adjustment
mode.
Setting
Default
range
0 - 127
64
64
64
64

Hide quick links: