Advertisement

Cooling down (not DW20.1)
Machines with softener : Cool down step is NOT performed during regeneration.
Drain pump
Inlet valve
Circulation pump
Drain pump
Pre-rinse
Inlet valve
Circulation pump
Drain pump
1st. Rinse
Inlet valve
Circulation pump
Circulation pump
Drain pump
Circulation pump
Drain pump 25 sec
Drain pump Inlet valve
Drain pump 8 sec
Final rinse
Inlet valve
Circulation pump
Circulation pump, Heater
Circulation pump
Circulation pump, Combined dispenser
Circulation pump
Circulation pump
Pause
Drain pump
Drying
Fan
5 sec
24 sec
60 sec
25 sec
170 pulse* , 14 sec, 0.9 lit EU
20 sec, Lower arm low pressure**
25 sec
605 pulse*, 47 sec, 3.1 lit***
545 pulse*
43 sec, 2.8 lit EU**
4 min
60 sec, Upper arm high pressure**
2 sec SCS stage
20 sec SCS stage Upper arm high pressure**
100 pulse, 8 sec, 0,5 lit
605 pulse*, 47 sec, 3.1 lit***
545 pulse* 43 sec, 2.8 lit EU**
60 sec
65°C (70ºC in machines without drying selection)
Temperature stop
3 sec
60 sec
4 min
50 sec
Upper arm high pressure**
60 sec
25 sec
30 min
39