Asko DW20.1 Service Manual page 37

Hide thumbs Also See for DW20.1:
Table of Contents

Advertisement

Cooling down (not DW20.1)
Machines with softener : Cool down step is NOT performed during regeneration.
Drain pump
Inlet valve
Circulation pump
Drain pump
Pre-rinse
Inlet valve
Circulation pump
Drain pump
1st. Rinse
Inlet valve
Circulation pump
Circulation pump
Drain pump
Circulation pump
Drain pump
Final rinse
Inlet valve
Circulation pump
Circulation pump, Heater
Circulation pump, Combined dispenser
Circulation pump
Circulation pump
Pause
Drain pump
Drying
Fan
5 sec
24 sec
60 sec
25 sec
170 pulse*, 14 sec, 0.9 lit
20 sec, Lower arm low pressure **
25 sec
605 pulse*, 47 sec, 3.1 lit***
545 pulse* 43 sec, 2.8 lit**
9 min
60 sec, Upper arm high pressure**
2 sec SCS stage
20 sec SCS stage, Upper arm high pressure **
25 sec
605 pulse*, 47 sec, 3.1 lit***
545 pulse* 43 sec, 2.8 lit**
60 sec
60°C Temperature stop
60 sec
4 min
50 sec, Upper arm high pressure **
60 sec
25 sec
48 min
S E R V I C E M E N U
S E R V I C E M E N U
S E R V I C E M E N U
S E R V I C E M E N U
S E R V I C E M E N U
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dw20.2Dw20.3Dw20.4Dw20.5Dw20.c

Table of Contents