DW20.3
1.
Turn off the main switch (I/0)
2.
Wait for at least 5 seconds
3.
Keep the Programme and Start buttons
depressed (S1 & S2)
4.
Turn on the main switch (I/0)
5.
Release the Programme and Start buttons
(S1 & S2)
The most recent fault is indicated as L1-L6.
Press the Programme button (S1) and index
through the following components.
1.
Inlet valve
2.
Salt valve (only machines with water
softener)
3.
Detergent and surfactant dispenser
4.
Circulation pump
5.
Heating element and circulation pump
(Max 75°C)
6.
Fan
7.
Drain pump
Water intake adjusting
Keep the Programme button depressed for three
seconds to adjust the water intake.
Machines manufactured before year 2005
week 16
Press the Programme button and index through
the following:
L1-L6 extinguished: Normal water intake volume
L1 lit: Water intake volume is reduced by 10%
L2 lit: Water intake volume is reduced by 5%
L3 lit: Time-controlled water intake
L4 lit: Water intake volume is increased by 5 %
L5 lit: Water intake volume is increased by 10 %
L6 lit: Water intake volume is increased by 15 %
Confirm your choice by pressing Start (S2). The
programme returns to the main menu.
Machines manufactured year 2005 week 16
and later
Press the Programme button and index through
the following:
L1-L6 extinguished: Normal water intake volume
L1 lit: Water intake volume is increased by 5%
L2 lit: Water intake volume is increased by 10%
L3 lit: Time-controlled water intake
L4 lit: Water intake volume is increased by 5 %
time-controlled
L5 lit: Water intake volume is increased by 10 %
time-controlled
L6 lit: Water intake volume is increased by 15 %
time-controlled
Confirm your choice by pressing Start (S2). The
programme returns to the main menu.
DW20.4
1.
Turn off the main switch (I/0)
2.
Wait for at least 5 seconds
3.
Keep the Temperature/Set and Drying/
Menu buttons depressed (S3 & S4)
4.
Turn on the main switch (I/0)
5.
Release the Temperature/Set and Drying/
Menu buttons (S3 & S4)
Press Temperature/Set (S3) for information about:
-
Date code (year/week) and serial number
-
Control unit date code
-
Software version
-
Most recent fault
-
Next most recent fault
(if different from the most recent fault)
-
Third most recent fault
(if different from the two most recent faults)
Press Drying/Menu (S4) to access component
diagnostics.
Press Temperature/Set (S3) to activate the
following components:
1.
Inlet valve (display shows water intake
volume)
2.
Salt valve (only machines with water softener)
3.
Detergent and surfactant dispenser
4.
Circulation pump (display shows turbidity in
Volts)
5.
Heating element and circulation pump (Max
75°C) (Display shows temperature, see table)
6.
Fan (display shows humidity sensor value)
7.
Drain pump (display shows pressure sensor
reading; 0.5-3.5 VDC)