Performance Data - Maytag AFU1202BW Service

Upright freezers
Table of Contents

Advertisement

Component Testing
!
WARNING
power to be connected. When removing any wiring from terminals they must be replaced on the same terminals.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Capacity
Insulation
Cu. Ft.
Type
11.6
Foam
15.2
Foam
16.8
Foam
19.6
Foam
15.0
Foam
16.8
Foam
19.6
Foam
22
Performance Data at Control Setting # 4
Manual Defrost
Amb
Wattage
Running
70°
90−110
35−45
90°
95−115
50−60
110°
100−120
80−90
70°
95−115
35−45
90°
100−120
55−65
110°
105−125
90−100
70°
105−125
40−50
90°
110−130
55−65
110°
115−135
90−100
70°
120−140
40−50
90°
125−145
55−65
110°
130−150
90−100
Performance Data at Control Setting # 4
Auto Defrost
70°
125−145
45−55
90°
130−150
60−70
110°
135−155
90−100
70°
135−155
35−45
90°
140−160
45−55
110°
145−165
90−100
70°
135−155
40−50
90°
140−160
60−70
110°
145−165
90−100
16023585
To avoid risk electrical shock, personal injury, or death,
always disconnect electrical power source to the freezer
before attempting to service, unless test procedures require
%
High
Low
Side
Side
−5 −3
95−115
−4 −2
125−145
−2
170−190
−4 −2
95−115
−3 −1
125−145
−3 −1
165−185
−4 −2
95−115
−3 −1
130−150
−2
165−185
−4 −2
100−120
−3 −1
135−155
−1 −1
175−195
−3 −1
105−125
−3 −1
140−160
−1
185−205
−3 −1
100−120
−2
135−155
−2
175−195
−4 −2
95−115
−4 −2
130−150
−2
175−195
Amps
Running
Capacitor
12 uF
0.7−1.0
210 V
0.8−1.1
0
0.8−1.1
0.9−1.2
12 uF
210 V
0.9−1.2
1.0−1.3
0.9−1.2
12 uF
210 V
0.9−1.2
1
1.0−1.3
1.0−1.3
12 uF
210 V
1.0−1.3
1.2−1.5
1.0−1.3
12 uF
210 V
1.1−1.4
1
1.2−1.5
1.2−1.5
12 uF
210 V
0
1.2−1.5
0
1.2−1.6
1.2−1.5
12 uF
210 V
1.2−1.5
0
1.3−1.6
©2004 Maytag Services