Charging System; Control System - Yamaha WaveRunner VX 700 Service Manual

Table of Contents

Advertisement

Charging system

Item
Charge coil
Output peak voltage
at cranking (unloaded)
at cranking (loaded)
at 1500 r/min (loaded)
at 3500 r/min (loaded)
Resistance (*1)
at 20 °C (68 °F)
Lighting coil
Output peak voltage
at cranking (unloaded)
at 1500 r/min (unloaded)
at 3500 r/min (unloaded)
Resistance (*1)
at 20 °C (68 °F)
Minimum charging
current
Rectifier regulator
Output peak voltage
at 3500 r/min (loaded)
(*1) The figures are for reference only.

Control system

Item
Ignition coil
Primary coil resistance
at 20 °C (68 °F)
Secondary coil resistance
at 20 °C (68 °F)
Thermoswitch (engine)
Input voltage (*1)
Continuity temperature
No continuity temperature
(*1) The figures are for reference only.
Jet pump unit technical data / Electrical technical data
Unit
V
V
V
V
V
V
V
A at r/min
V
Unit
kΩ
V
°C (°F)
°C (°F)
Model
VX 700
180
20
210
150
497.7–608.3
8.7
25.6
47.3
1.143–1.397
14 at 6000
13.0
Model
VX 700
0.078–0.106
14.336–30.464
11.0–12.0
77–83 (171–181)
63–77 (145–171)
1
2
3
4
5
6
7
8
9
A
2-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Waverunner vx 700 f2v