Support For Association Groups - Remotec ZTS-110 Z-Thermostat User Manual

Z-wave enabled programmable thermostat
Hide thumbs Also See for ZTS-110 Z-Thermostat:
Table of Contents

Advertisement

Exclusion is completed. 
Press  "Home"  key once to go 
back to the home page. 
  will disappear on the main 
display 
 
 
Support for Association Groups 
ZTS‐110 supports 3 association groups. 
Association group 
 
Mode 
Heating mode 
Cooling mode 
OFF 
 
Association group_3:  (Auto report) 
Association group_3 is used to report status change to gateway. 
(Only gateway or controller can be assigned in this association group) 
ZTS‐110 will trigger AUTO report function if one of below status is changed.   
I.
Operation mode (Off, Heat, Cool, Auto)   
II.
Operation state (Heat on or off, Cool on or off)   
III.
Fan mode (Auto, Auto low)   
IV.
Fan state (Fan on or Fan off) 
V.
Heat set point (report in precision 1 after decimal, e.g. 21.1
VI.
Cool set point (report in precision 1 after decimal, e.g. 23.3
VII.
Current room temperature (report in precision 1 after decimal, e.g. 24.0
(It will trigger room temperature report if there is 4
You can change this setting by set the configuration parameter)   
Association group_1   
(Heat pump) 
ON 
(basic set command 0xFF)
OFF 
(basic set command 0x00)
OFF 
(basic set command 0x00) 
Association group_2 
(Compressor) 
OFF 
(basic set command 0x00) 
ON 
(basic set command 0xFF) 
OFF 
(basic set command 0x00) 
o
C ) 
o
C ) 
o
o
F or 2
C (default) differ from last report. 
30
Association group_3 
(Auto Report) 
‐ 
‐ 
‐ 
o
C)   