Remotec ZTS-110 Z-Thermostat User Manual page 29

Z-wave enabled programmable thermostat
Hide thumbs Also See for ZTS-110 Z-Thermostat:
Table of Contents

Advertisement

If the ZTS‐110 is added into the 
network successfully, the signal of 
"done" will appear. 
Press  "Home"  key once to go 
back to the home page.   
  will appear on the main 
display.   
 
Note:   
It is recommended to perform the Delete/Exclude procedure before doing Add/Include. This is to 
make sure the ZTS‐110 is not in any other Z‐Wave network which will result in failure in Inclusion 
process.   
If the inclusion is failed, try exclusion, and/or reset ZTS‐110 to factory default and try inclusion again.    
After ZTS‐110 is included to Z‐Wave network, it will stay in Easy mode by default.  
You can enable or disable Easy mode by local "Setting Mode" or Z‐Wave parameter number 8.  
(please refer to parameter table at Z‐Wave Configuration Parameters).  
 
 
Delete (Exclude) ZTS‐110 from Gateway / Controller Z‐Wave network 
Step  Procedure / Description 
Gateway / Controller device should 
be set to Exclusion mode. 
 
Press and hold  "Home" key for 2 
seconds to set ZTS‐110 to Add 
(Include) / Delete (Exclude) Mode. 
Press  "Prog"  key once, it will 
search the network. 
If the ZTS‐110 is removed from the 
network, it shows no connection. 
LCD indication 
29