Activate/Deactivate Easy Mode 
The ZTS‐110 is default with Easy mode, below illustrates the functions of Easy mode: 
• Active functions:    Change Mode, change Fan mode and Temperature Scale selection 
• Inactive functions:  Scheduling, Program Mode, Clock Display, Setting Time, Setting Swing, Setting, 
Differential Set‐Point and Advanced Recovery Mode 
 
User can use Easy mode to disable Schedule function and the schedule will be controlled by Z‐Wave 
gateway. User can still change temperature and mode by pressing the local physical buttons. 
User can deactivate the Easy mode by local "Setting Mode" or Z‐Wave Configuration Parameter number 
8. (Please refer to Z‐Wave Configuration parameters table). 
 
Below is the example by local setting: 
Step  Procedure / Description 
Press and hold  "Mode" key for 2 
seconds to entry the setting mode.
It will display "EASY YES" if it stays 
in Easy mode. Otherwise,   
it will display "EASY no" if Easy 
mode is  deactivated . 
 
Press Up/Down key to toggle the 
1
selection. 
Press  "Prog"  key to confirm 
your settings. 
‐ It will go back to Home page if 
selected "YES". 
‐ it will go to Day setting if selected 
"no". 
 
 
Temperature Scale selection in Easy Mode 
 
Step  Procedure / Description 
Press and hold  "Prog"  keys for 
2 seconds to entry temperature F 
(Fahrenheit) ‐> C (Celsius) selection 
mode. 
 
Press Up/Down key to toggle the 
temperature F (Fahrenheit) ‐>     
C (Celsius) selection. 
LCD indication 