    Z-Wave Add (Inclusion) / Delete (Exclusion) Mode ..18 Delete ZTS-100 from Gateway / Controller Z-Wave network 19 Add ZTS-100 to Gateway / Controller Z-Wave network ..19 Filter counter ..............20 Reset ZTS-100 to factory default settings ...... 21 Battery Low indication ...........
  • Page 3: Introduction

    Also, it is allow to control / check your room temperature by the smart phone or PC while you are at office, home anywhere or around the world which can go through the Z-Wave gateway control. ZTS-100 also supports batteries operation that can provide flexibility if there is out of 24VAC power line.
  • Page 4 Heat Pump change over valve: Selectable change over with cool or with heat Power: Powered by alkaline batteries AA x 4pcs or 24Vac Program Style: 2 program modes for scheduling (Mo-Fr, Sa-Su) 4 Separate Time and Temperature Settings for each program Heat and Cool set-points for each program Temporary Program Override Permanent Program Override...
  • Page 5: Glossary

    Glossary Devices and nodes are all terms to describe an individual Z-Wave Device or Node device. These are all interchangeable when setting up your Z-Wave network. Inclusion Add a Z-Wave device to the network. Exclusion Delete a Z-Wave device from the network.
  • Page 6: Physical Installation And Wiring

    − Use new batteries of the recommended type and size only. − Never mix used and new batteries together. − To avoid chemical leaks, remove batteries from the ZTS-100 if you do not intend to use the unit for an extended period of time.
  • Page 7 Connect the “24VAC Common” (typically the Blue wire/terminal) and “24VAC Return” (typically the Red wire/terminal) from the HVAC system to the ZTS-100 HVAC System terminal block “C” and “RH” or “RC” terminals (the RH and RC terminals are default tied together).
  • Page 8: Jumper Settings For Electh-Hpump And He-Hg

    Jumper settings for ELECTH-HPUMP and HE-HG: Jumper Function Description Set to ELECTH for non heat pump system Set to HPUMP for heat pump system Set to HG for Gas heat-fan controlled unit Set to HE for Electrical heat-fan controlled unit...
  • Page 9: Mounting

    Mounting: Open the ZTS-100 by pushing the hook (Figure 5) Install AAx4pcs batteries if using battery power (Alkaline batteries are recommended) Check the polarity of the batteries and the "+/-" marks inside the battery compartment Connect 24Vac common at C terminal if using 24Vac power...
  • Page 10: Zts-100 Z-Thermostat Operations

    ZTS-100 Z-Thermostat Operations The following section will guide you through the set up processes for your ZTS-100. Please note that all Z-Wave thermostat controllers made from various vendors are compatible with your ZTS-100 as long as they carry the Z-Wave logo: (Please carefully read through the following then store the manual for future reference.)
  • Page 11: Normal Operation Mode

    Normal Operation Mode Change Operation mode Note 1: In Heat mode => it displays “HEAT” if ELECTH is selected. => it displays “HEAT PUMP” if HPUMP is selected. Step Procedure / Description LCD indication Press “Mode” key once to change the operation mode: OFF ->...
  • Page 12: Select Fan Mode

    Select Fan mode Step Procedure / Description LCD indication Press “Fan” key once to change the Fan mode: FAN AUTO -> FAN ON FAN AUTO: Electric heat (HE): Fan runs only when Heating/Cooling is running. Gas heat (HG): Fan runs only when Cooling is running.
  • Page 13: Override/Permanent Override

    Override/Permanent Override Note 1: Override/Permanent Override only available in HEAT, COOL or AUTO mode. Step Procedure / Description LCD indication Press “Prog” key once to select PROG mode: OVERRIDE or PERMANENT OVERRIDE at Home page. Press Up/Down key to adjust set point temperature in HEAT or COOL mode.
  • Page 14: Setting Mode

    Setting Mode (set Day, Clock, 12/24 hour, F/C, Swing and Diff.) Symbol Setting Mode Key Description Increase value / Toggle selection Decrease value / Toggle selection Backward to previous setting Forward to next setting Confirm and go to next setting Confirm and back to Home Setting mode: Step Procedure / Description...
  • Page 15 Press “Prog" key once to confirm the setting and it will go to 12/24 hour clock selection. Press Up/Down key to toggle the ⇓ 12/24 hour clock selection. Press “Prog" key once to confirm the setting and it will go to temperature F ->...
  • Page 16: Setting Schedule

    Press “Prog" key once to confirm the setting and it will go to the Home page. Setting schedule Default schedule: Event Time Heat Cool WAKE 6:00 AM 70 °F (21°C) 78 °F (26°C) AWAY 8:00 AM 62 °F (17°C) 85 °F (29°C) HOME 6:00 PM 70 °F (21°C)
  • Page 17 ⇓ ⇓ Press “Prog" key once to confirm the setting and it will go to hour setting. Hour will keep flashing, press Up/Down key to set hour. Press “Prog" key once to confirm the setting and it will go to minutes setting.
  • Page 18: Z-Wave Add (Inclusion) / Delete (Exclusion) Mode

    ZTS-100 has been added into the Z-Wave network. Please perform the Delete (Exclusion) before add into the new Z-Wave network. Note 2: User can control the ZTS-100 through gateway or controller after added into the Z-Wave network.
  • Page 19: Delete Zts-100 From Gateway / Controller Z-Wave Network

    Delete (Exclusion) ZTS-100 from Gateway / Controller Z-Wave network Step Procedure / Description LCD indication Gateway / Controller device should entry the Exclusion mode. Press and hold “Home” key for 2 seconds to entry the Add (Inclusion) / Delete (Exclusion) Mode.
  • Page 20: Filter Counter

    Press “Prog" key once, it will search the network. If the ZTS-100 is added into the network, it shows done. Inclusion is done. Press “Home" key once to back to the home page. Filter counter Step Procedure / Description LCD indication Press and hold “Fan”...
  • Page 21: Reset Zts-100 To Factory Default Settings

    Reset ZTS-100 to factory default settings Step Procedure / Description LCD indication Press and hold “Fan ” + “Mode" keys for 2 seconds to entry the reset mode. Press Up/Down key to toggle ⇓ Yes/No selection. Press “Prog" key once to confirm the action.
  • Page 22: Battery Low Indication

    Battery Low indication Step Procedure / Description LCD indication ZTS-100 thermostat will detect the battery level every 30 minutes; Battery low icon will be displayed at Home page if the battery is running out. (User is needed to replace new batteries.)
  • Page 23: Advance Recovery Indication

    Advance Recovery indication Step Procedure / Description LCD indication The Advance Recovery feature allows heating and cooling systems to gradually recover from an energy-saving set point temperature to a comfort set point temperature. Advance Recovery calculates the time needed to adjust the temperature to the next program setting for the Morning and Evening schedules.
  • Page 24: Short Cycle Start Up Protection

    ZTS-100. All Z-Wave products also come with the Z-Wave logo. Q Can I use 2 or more ZTS-100 in my house? What is the max. units if yes? A Yes and it is very depend on the capability of gateway / controller. For example, gateway can supports up to 8, 16 or 32 ZTS-100 in a network.
  • Page 25 => 2nd stage heater turns on when room temp is 67 °F and off at 70 °F. COOL Mode: thermostat controls the temperature according to the following diagram Set point Cool Turn off Turn on Temperature Swing Example for Cooling: (Set point = 80 °F, Swing = 1 °F) =>...
  • Page 26: Technical Specifications

    Storage: 23 – 140 °F / -5 – 60 °C Dimension (L x H x T) 145mm x 100mm x 25mm Weight 170g (Batteries excluded) Z-Wave device type Basic Device Class: Routing_Slave (Enhanced_Lib) Generic Device Class: Thermostat Specific Device Class: Thermostat general v2 Z-Wave Command Class...
  • Page 27: Checking The Accessories

    CHECKING THE ACCESSORIES After opening the cover of the packing box, check that the following accessories are included. • ZTS-100: Z-Thermostat • Screw x 4pcs • User Manual (download from our website) FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two...