Trigger AUTO report if room 
temperature is different 
from last report. 
(It will report room 
temperature only) 
 
*User can use this function 
to enhance batteries service 
life. 
AUTO report by time 
interval. 
(It will report room 
temperature only) 
 
*User can use this function 
to enhance batteries service 
life. 
11 (0x0B) 
12 (0x0C) 
33
0 (0x00) = disable AUTO report if room 
temperature is different from last 
report. 
 
AUTO report if room temperature is 
different from last report. 
Delta change is >= 
o
o
1 (0x01) = 1
F (0.5
C) 
o
o
2 (0x02) = 2
F (1.0
C) 
o
o
3 (0x03) = 3
F (1.5
C) 
o
o
4 (0x04) = 4
F (2.0
C), default 
o
o
5 (0x05) = 5
F (2.5
C) 
o
o
6 (0x06) = 6
F (3.0
C) 
o
o
7 (0x07) = 7
F (3.5
C) 
o
o
8 (0x08) = 8
F (4.0
C) 
0 (0x00) = disable AUTO report 
function (by time interval) 
 
AUTO report timer: 
1 (0x01) = 0.5 hr 
2 (0x02) = 1.0 hr, default 
3 (0x03) = 1.5 hrs 
4 (0x04) = 2.0 hrs 
5 (0x05) = 2.5 hrs 
6 (0x06) = 3.0 hrs 
7 (0x07) = 3.5 hrs 
8 (0x08) = 4.0 hrs 
9 (0x09) = 4.5 hrs 
10 (0x0A) = 5.0 hrs 
11 (0x0B) = 5.5 hrs 
12 (0x0C) = 6.0 hrs 
13 (0x0D) = 6.5 hrs 
14 (0x0E) = 7.0 hrs 
15 (0x0F) = 7.5 hrs 
16 (0x10) = 8.0 hrs 
 
 
 
 
 
 