There is a dead band 4°F/2°C between heat set point and cool set point. 
Example 1: If user select heat set point is 70F, the minimum cool set point will be limited   
 
 
at "heat set point + 4°F: 74°F 
 
Pervious heat set point is 70°F and cool set point is 74°F 
Example 2: If user changes heat set point to 72F, cool set point will be updated to 76°F   
 
 
automatically to maintain the dead band. 
Change Mode 
 
  N ote: In Heat mode => it displays "HEAT" if ELECTH is selected during jumper setting.   
   
 
 
 
Below example is based on HEAT PUMP 
Step  Procedure / Description 
Press "Mode" key once to change 
the operation mode: 
OFF ‐> HEAT (PUMP) ‐> COOL ‐> 
AUTO ‐> OFF 
=> it displays "HEAT PUMP" if HPUMP is selected during jumper setting. 
LCD indication 
18
 