Support Association Groups (Association Command Class)
ZTS-110 supports 3 association groups.
Association group
Association group_1
(Heat pump)
Mode
ON
Heating mode
(basic set command 0xFF)
OFF
Cooling mode
(basic set command 0x00)
OFF
OFF
(basic set command 0x00)
Association group_3: (Auto report)
- Association group_3 is used to report status change to gateway. (Only gateway
or controller can be assigned in this association group)
ZTS-110 will trigger AUTO report function if one of below status is changed.
I. Operation mode (Off, Heat, Cool, Auto)
II. Operation state (Heat on or off, Cool on or off)
III. Fan mode (Auto, Auto low)
IV. Fan state (Fan on or Fan off)
V. Heat set point (report in precision 1 after decimal, e.g. 21.1 C )
VI. Cool set point (report in precision 1 after decimal, e.g. 23.3 C )
VII. Current room temperature (report in precision 1 after decimal, e.g. 24.0 C)
(It will trigger room temperature report if there is 4 F or 2 C (default) differ from
last report. You can change this setting by set the configuration parameter)
Note: Total 5 devices (nodes) can be assigned in total 3 association groups. Below
table lists out the devices (nodes) allocations in the 3 association groups.
No. of Node ID in
No. of Node ID in
Case No.
Association group_1
Association group_2
Case 1
4
Case 2
3
Case 3
2
Case 4
1
Case 5
0
Important: Please do not associate heat pump and compressor devices in same
association group because heat pump and compressor device cannot be turned on
simultaneously!
29
Association Groups setting example (case 3):
Association group_2
(Compressor)
OFF
(basic set command 0x00)
ON
(basic set command 0xFF)
F-BW8041 (ZFM-80)
(Node ID-A)
OFF
(basic set command 0x00)
o
F-BW8041 (ZFM-80)
(Node ID-C)
o
o
o
o

Z-Wave Configuration Parameters

Different user has different preferred settings of their thermostat, you may use the
below configuration parameters to change settings of corresponding functionality.
No. of Node ID in
Association group_3
Swing
0
1 (AUTO report)
1
1 (AUTO report)
2
1 (AUTO report)
Differential
3
1 (AUTO report)
4
1 (AUTO report)
Set filter counter
Association group_1
for Heat Pump
F-BW8041 (ZFM-80)
F-BW8031 (ZTS-110)
(Node ID-B)
Association group_2
for Compressor
F-BW8041 (ZFM-80)
(Node ID-D)
Functions
Parameter No.
Parameter value range
o
1 (0x01) = 1 F / 0.5 C
2 (0x02) = 2 F / 1.0 C (default)
o
1 (0x01)
o
3 (0x03) = 3 F / 1.5 C
o
4 (0x04) = 4 F / 2.0 C
o
1 (0x01) = 1 F / 0.5 C
2 (0x02) = 2 F / 1.0 C (default)
o
2 (0x02)
o
3 (0x03) = 3 F / 1.5 C
o
4 (0x04) = 4 F / 2.0 C
500 (0x01F4) to 4000 (0x0FA0) hours
3 (0x03)
Default = 500 (0x01F4) hours
Resolution = 100 (0x0064) hours
30
Association group_3
for Auto report to
gateway
Z-Wave Gateway
(Node ID-E)
o
o
o
o
o
o
o
o