Short Cycle Start Up Protection 
To protect the compressor / Heat pump, those outputs forced off until 3minutes count down 
finished. Those outputs can be activated according to the room temperature after 3 minutes. 
System 
Non Heat pump system 
Heat pump system 
 
Energy Saving Mode 
Step  Procedure / Description 
User can enable/disable energy 
saving mode by using Z‐Wave 
BASIC set command only. (you may 
refer to the Z‐Wave primary 
controller UI for it)   
 
=> Enable energy saving mode
 
Basic set value = 0x00 (Off) 
 
(energy saving mode will be mapped 
 
to off mode) 
 
=> Disable energy saving mode   
 
Basic set value = 0xFF (Resume) 
 
(comfort mode will mapped to 
 
resume mode)
 
Z‐Wave Setup and Operations 
Setting FLiRS or Always Listening mode 
Setting to Z‐Wave FLiRS mode with batteries as power source 
ZTS‐110 will self‐configure to FLiRS mode if it is powered by batteries or powered by batteries first 
then  applied  with  24Vac  before  Z‐Wave  inclusion.  FLiRS  mode  is  targeted  for  battery  operated 
applications and will enter sleep mode frequently in order to save battery life. ZTS‐110 can't act as 
a  repeater  in  this  mode.  The  response  to  Z‐Wave  command  is  not  as  quick  as  Always  Listening 
Device. Normally there is 1‐2 seconds latency on response, you should avoid sending commands to 
ZTS‐110 too frequently.   
   
Setting to Z‐Wave Always Listening mode with 24Vac as power source 
ZTS‐110 will self‐configure to Always Listening Mode if it is powered by 24Vac or powered by 24Vac 
first then applied with batteries before Z‐Wave inclusion. Always Listening mode is targeted for AC 
power  operated  applications  and  it  can  act  as  a  repeater  which  will  re‐transmit  the  RF  signal  to 
ensure that the signal is received by its intended destination by routing the signal around obstacle 
and radio dead spots. The response to Z‐Wave command is immediate. 
 