To Stop Vertical airflow SWING Operation
Press the VERTICAL SWING button for more than two seconds
once and again.
The remote controller's VERTICAL SWING lamp **and indoor
unit's SWING indicator lamp (VERTICAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
Instructions relating to "the indoor unit's indicator lamp" (**) are
applicable to "LARGE CEILING TYPE", "UNIVERSAL FLOOR /
CEILING TYPE", "CASSETTE TYPE", "WALL MOUNTED TYPE",
"COMPACT WALL MOUNTED TYPE" and "CEILING WALL TYPE".
About Vertical Airflow SWING Operation
The range of swing is relative to the currently set airflow direc-
tion.
If the swing range is not as desired, use the remote controller's
VERTICAL AIR FLOW DIRECTION SET button to change the
range of swing.
The SWING operation may stop temporarily when the air condi-
tioner's fan is not operating, or when operating at very low
speeds.
To select Horizontal Airflow SWING Operation
This instructions are applicable to "LARGE CEILING TYPE",
"UNIVERSAL FLOOR / CEILING TYPE", "WALL MOUNTED TYPE"
and "CEILING WALL TYPE".
Press the HORIZONTAL SWING button for more than two seconds.
The remote controller's HORIZONTAL SWING lamp (orange)
**and indoor unit's SWING indicator lamp (HORIZONTAL
SWING) (orange) will light up.
In this mode, the RIGHT/LEFT air direction louvers will swing
automatically to direct the airflow both right and left.
To stop Horizontal airflow SWING Operation
Press the HORIZONTAL SWING button for more than two seconds
once and again.
The remote controller's HORIZONTAL SWING lamp **and indoor
unit's SWING indicator lamp (HORIZONTAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.
About Horizontal Airflow Swing Operation
The range of swing is relative to the currently set airflow direc
tion.
If the swing range is not as desired, use the remote controller's
HORIZONTAL AIR FLOW DIRECTION SET button to change
the range of swing.
The SWING operation may stop temporarily when the air condi-
tioner's fan is not operating, or when operating at very low speed.
Air swing range (Expect for compact wall mounted type indoor unit)
Air flow direction set
Air swing range (Compact wall mounted type indoor unit)
Air flow direction set
Example : When set to horizontal swing.
Air flow direction set
05-06
Range of swing
1
1
2
2
2
3
1
to
4
4
Range of swing
or
2
1
1
2
3
1
4
DAY
DAY OFF
CLOCK ADJUST
ENERGY
THERMO
SET BACK
SAVE
SENSOR
DELETE
SET
Air swing range
Range of swing
to
1
1
5
2
1
3
2
4
3
5
1
to
5
Air direction range
to
3
to
4
to
4
(All range)
to
2
to
4
to
4
(All range)
to
3
to
4
to
5
(All range)