Appendix B - Ul Listed Compatible Devices - Altronix FireSwitch108 Installation Manual

Nac power extender
Table of Contents

Advertisement

Appendix A - UL/cUL Listed Compatible Devices for Synchronization (cont'd)
A-1 Strobes, Horns and Horn/Strobes
Table A-1 below lists Strobes, Horns and Horn/Strobes compatible with FireSwitch NAC outputs.
Potter:
SSR2-177W - UL
SSR8-3075110R - UL
SSR8-3075110W - UL
SSR8-177R - UL
SSR8-177W - UL
Cooper/Wheelock:
CH70-24MCW-FR - UL/cUL
CH70-24MCW-FW - UL/cUL
CH70-24MCWH-FR - UL/cUL
CH70-24MCWH-FW - UL/cUL
CH90-24MCC-FR - UL/cUL
CH90-24MCC-FW - UL/cUL
CH90-24MCCH-FR - UL/cUL
CH90-24MCCH-FW - UL/cUL
AMT-24MCW-FR - UL/cUL
AMT-24MCW-FW - UL/cUL
AMT-241575W-FR - UL/cUL
AMT-241575W-FW - UL/cUL
AMT-241575W-FR-NYC - UL
AS-12100C - UL/cUL
AS-24100C - UL/cUL
HSR - UL/cUL
HSW - UL/cUL
HSRC - UL/cUL
HSWC - UL/cUL
HS4-24MCW-FR - UL/cUL
HS4-24MCW-FW - UL/cUL
HS4-24MCC-FW - UL/cUL
HS4-24MCC-FR - UL
HS4-241575W-FR - UL/cUL
S8-24MCC-FW - UL/cUL
S8-24MCCH-FW - UL/cUL
E50-24MCW-FR - UL/cUL
B.1 Four (4) Wire Smoke Detectors
Table B-1 below lists four (4) wire smoke detectors compatible with FireSwitch AUX output and Outputs 1-8 when pro-
grammed as AUX.
System Sensor
Smoke Detector/Base
B112LP
B114LP
B404B
DH100ACDC
DH100ACDCLP
DH100ACDCLPW
DH400ACDCI
DH400ACDCP
1112/24/D
1424
1451 (w/B402B Base)
- 18 -
CM24CR - UL
CM24CW - UL
SCM24C-3075110R - UL
SCM24C-3075110W - UL
SCM24C-177R - UL
E50-24MCW-FW - UL/cUL
E50-24MCWH-FR - UL/cUL
E50-24MCWH-FW - UL/cUL
E50-241575W-FR - UL/cUL
E50-241575W-FW - UL/cUL
E60-24MCC-FR - UL/cUL
E60-24MCC-FW - UL/cUL
E60-24MCCH-FR - UL/cUL
E60-24MCCH-FW - UL/cUL
E90-24MCC-FR - UL/cUL
E90-24MCC-FW - UL/cUL
E90-24MCC-FN - UL/cUL
E90-24MCCH-FR - UL/cUL
E90-24MCCH-FW - UL/cUL
E90-24MCCH-FN - UL/cUL
E70-24MCW-FR - UL/cUL
E70-24MCW-FW - UL/cUL
E70-24MCW-FN - UL/cUL
E70-24MCWH-FR - UL/cUL
E70-24MCWH-FW - UL/cUL
E70-24MCWH-FN - UL/cUL
ET70-24MCW-FR - UL/cUL
ET70-24MCW-FW - UL/cUL
ET70-24MCW-FN - UL/cUL
ET70-24MCWH-FR - UL/cUL
ET70-24MCWH-FW - UL/cUL
ET70-24MCWH-FN - UL/cUL

Appendix B - UL Listed Compatible Devices

Detector Type
Base
Base
Base
Photoelectric
Photoelectric
Photoelectric
Ionization Duct
Photoelectric Duct
Ionization
Ionization
Ionization
SCM24C-177W - UL
HP-25TR - UL/cUL
HP-25TW - UL/cUL
ET70-241575W-FR - UL/cUL
ET70-241575W-FW - UL/cUL
ET70-241575W-FN - UL/cUL
ET90-24MCC-FR - UL/cUL
ET90-24MCC-FW - UL/cUL
ET90-24MCC-FN - UL/cUL
ET90-24MCCH-FR - UL/cUL
ET90-24MCCH-FW - UL/cUL
ET90-24MCCH-FN - UL/cUL
ET80-241575W-FR - UL/cUL
ET80-241575W-FW - UL/cUL
ET80-24MCW-FR - UL/cUL
ET80-24MCW-FW - UL/cUL
ET80-24MCWH-FR - UL/cUL
ET80-24MCWH-FW - UL/cUL
RSS-24MCW - UL/cUL
SA-S70-24MCW-FR - UL
SA-S70-24MCW-FW - UL
SA-S90-24MCC-FR - UL
SA-S90-24MCC-FW - UL
MIZ-24S-R - UL/cUL
MIZ-24S-W - UL/cUL
HNR - UL/cUL
HNW - UL/cUL
HNRC - UL/cUL
HNWC - UL/cUL
Max Stand-by Current (mA) Alarm Current (mA)
0.12
*
*
0.15
0.15
0.15
25
25
0.05
0.10
0.10
36
*
*
0.70
0.70
0.70
95
95
50
41
39