Pll Adjustment; Receiver Adjustment - Icom IC-706 Service Manual

Hf/vhf
Hide thumbs Also See for IC-706:
Table of Contents

Advertisement

4-2 PLL ADJUSTMENT
MEASUREMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITIONS
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
REFERENCE
1 • Displayed frequency:
Any
PLL
Connect an RF voltmeter
Maximum level
PLL
L37,L38
FREQUENCY
• L36 (PLL unit)
:
Center
to P3.
(0 dBm or more)
I--
• Receiving
2
Connect a frequency
60.000000 MHz
L34,L36
counter to P3.
REFERENCE
1 • Displayed frequency:
0.03000 MHz
PLL
Connect a digital multi-
2.0 V
PLL
C104
LOOP LOCK
• Mode
USB
meter or oscilloscope to
VOLTAGE
• Receiving
LV1.
MAIN LOOP
1 • Displayed frequency:
30.00000 MHz
PLL
Connect a digital multi-
1.1 V
PLL
L6
LOCK
• Mode
: USB
meter or oscilloscope to
VOLTAGE
• Receiving
LV2.
2 • Displayed frequency:
60.00000 MHz
1.1 V
L3
4-3 RECEIVER ADJUSTMENT
MEASUREMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITIONS
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
SENSITIVITY
1 • Displayed frequency :
14.10000 MHz
Rear
Connect an AC millivolt-
Maximum output
MAIN
Adjust
• Mode
: USB
panel
meter to [EXT SP] jack
level
repeatedly
• (RIT]
: OFF
with an 8
n
dummy load.
L47, L48,
• [M4AGC)
: Fast (F
AGC)
L49, L53,
• [M3NB]
: OFF
L54, L55,
• [P.AMP/ATT]
: Preamp
L84,L85
• [COMP GAIN]
: Center
• (BEEP/SIDE T]
: Center
• [VOX GAIN]
: Center
• (ANTI VOX]
: Max. counterclockwise
• R126 (MAIN unit): Max. counterclockwise
• Connect a standard signal generator to
[ANT 1] and set as:
Frequency:
14.10150 MHz
Level
:
0.5 JiV'
H
13 dBm)
Modulation:
OFF
• Receiving
2 • Mode
FM
Connect a distortion
Minimum
Adjust
• [M3NAR]
:
OFF
meter to [EXT SP] jack.
distortion level
repeatedly
• Set the standard signal generator as:
L47, L48,
Frequency:
14.10000 MHz
L49
Level
:
0.5 mV • (-53 dBm)
Modulation:
1 kHz
Deviation
:
±5kHz
3 • [M3NARj
:
ON
Adjust
• Set the standard signal generator as:
repeatedly
Deviation: ±4 kHz
L53,L54
4 • Displayed frequency:
146.00000 MHz
PA
Adjust
• [M3 NARj
OFF
repeatedly
• Connect the standard signal generator to
L29,L30
[ANT 2] and set as:
frequency:
146.00000 MHz
Deviation
:
±3.5kHz
* This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
4-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents