Pll Adjustment - Icom IC-F1610 Service Manual

Hide thumbs Also See for IC-F1610:
Table of Contents

Advertisement

5-3 PLL ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITIONS
PLL LOCK
1
• Operating frequency : 136.000 MHz
VOLTAGE
• Receiving
2
• Operating frequency : 174.000 MHz
• Receiving
3
• Operating frequency : 136.000 MHz
• Transmitting
4
• Operating frequency : 174.000 MHz
• Transmitting
PLL
1
• Operating frequency : 174.000 MHz
REFERENCE
• Transmitting
FREQUENCY
• MAIN UNIT
L.V.
PLL lock voltage
check point
R376
Reference frequency
adjustment
MEASUREMENT
UNIT
LOCATION
MAIN
Connect a digital multi-
meter or an oscillo-
scope to the check
point, "LV".
Rear
Loosely couple a fre-
panel
quency counter to the
antenna connector.
5 - 3
ADJUSTMENT
VALUE
UNIT ADJUST
3.0 V
MAIN
10.0–14.0 V
3.0 V
10.5–15.5 V
174.00000 MHz
MAIN
L43
Tx PLL lock voltage
adjustment
L38
Rx PLL lock voltage
adjustment
L38
Verify
L43
Verify
R376

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents