Removing The Water Valve - KitchenAid KSBP25FKSS00 Technical Education

2001 k model counter depth side-by-side refrigerator with variable capacity compressor
Hide thumbs Also See for KSBP25FKSS00:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the refrigerator or disconnect the
power.
2.
Pull the refrigerator out of its mounting
location.
3.
Turn off the water supply to the refrigera-
tor.
4.
At the rear of the unit, remove the hex-
head screws from the unit compartment
cover and remove the cover.

REMOVING THE WATER VALVE

Water Valve
5.
Remove the hex-head screws from the
water valve bracket.
6.
Position a container under the water valve
to catch the water in the next step.
7.
Disconnect the 1/2" nut from the water
valve inlet tubing.
8.
Remove the water outlet tubing nuts from
the water valve.
9.
Remove the wire connectors from the two
solenoids.
Water Outlet Tubing Nuts
4-22
Water Valve
Bracket Screws
Wire Connectors
Water Valve
Inlet Tubing