Removing The Compressor - KitchenAid KSBP25FKSS00 Technical Education

2001 k model counter depth side-by-side refrigerator with variable capacity compressor
Hide thumbs Also See for KSBP25FKSS00:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the refrigerator or disconnect the
power.
2.
Pull the refrigerator out of its mounting
location.
3.
At the rear of the unit, remove the hex-
head screws from the unit compartment
cover and remove the cover.
Compressor
4.
Remove the inverter assembly (see page
4-17 for the procedure).
5.
Remove the compressor terminal cover.
To remove the cover, insert a flat-bladed
screwdriver into the top slot, push down on
the screwdriver to release the catch, and
then rotate the cover away from the com-
pressor at the top, and lift the cover off the
bottom catch (see the top right photo).

REMOVING THE COMPRESSOR

Filter/Drier
Compressor
Terminal Cover
6.
Remove the power connector and green
ground wire from the compressor termi-
nals.
7.
Loosen the strain relief screw and remove
the wire.
Terminal Cover
8.
Access the sealed system and discharge
the refrigerant into an approved recovery
system.
9.
Cut the suction and discharge lines.
10. Cut the filter/drier from the system (do not
use a torch to remove the filter/drier).
11. Pull the four clips from the compressor
mounting studs and remove the compres-
sor.
4-16
Power Connector & Ground Wire
Strain
Relief

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents