Component Testing; Thermistor - KitchenAid KSBP25FKSS00 Technical Education

2001 k model counter depth side-by-side refrigerator with variable capacity compressor
Hide thumbs Also See for KSBP25FKSS00:
Table of Contents

Advertisement

Before testing any of the components, perform
the following checks:
• The most common cause for control failure is
corrosion on connectors. Therefore, discon-
necting and reconnecting wires will be nec-
essary throughout test procedures.
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.

THERMISTOR

Refer to page 4-4 for the procedure for servic-
ing a thermistor.
1.
Run the diagnostics tests (see page 6-1)
and test the thermistors in steps 01 and
02.
NOTE: For accurate temperature/resistance
readings, continue with the remaining steps to
check the resistance of the thermistor(s).
2.
Unplug the refrigerator or disconnect the
power.
3.
Disconnect the thermistor wire connector
from the main harness.
4.
Set the ohmmeter to the R x 1K scale.
5.
Insert the test probes into the two connec-
tor pins of the thermistor connector.

COMPONENT TESTING

Electrical Shock Hazard
• Check all connections before replacing com-
ponents, looking for broken or loose wires,
failed terminals, or wires not pressed into
connectors far enough.
• Resistance checks must be made with power
cord unplugged from outlet, and with wiring
harness or connectors disconnected.
6.
Depending on the temperature, the meter
should indicate within the approximate
range, as shown in the chart below.
TEMPERATURE
RESISTANCE
(° ° ° ° F)
OHMS (APPROX.)
–5
25900-27500
0
22100-23500
5
18900-20000
10
16200-17200
15
13900-14800
20
12000-12800
25
10400-11000
30
8990-9550
32
8750
35
7800-8290
4 0
6800-7220
NOTE: If the resistance of the thermistor(s)
was normal, perform the following voltage test.
1.
Set the voltmeter to read a maximum
voltage of 10 volts DC.
2.
Connect power to the refrigerator and
allow it to enter the "cooling" mode.
3.
With the thermistor disconnected and the
refrigerator in the cooling mode, touch the
voltmeter test probes to the thermistor
main harness connector pins. The meter
should indicate approximately 5 volts DC.
If the voltage was not present, check for a
thermistor output at the main control board
(see page 5-5).
5-1
TEMPERATURE
RESISTANCE
(° ° ° ° F)
OHMS (APPROX.)
4 5
5930-6300
50
5190-5510
55
4550-4830
60
4000-4240
65
3520-3730
70
3100-3300
75
2740-2910
80
2430-2580
85
2160-2290
90
1920-2030

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents