23.6

Logging of Raw Obs

Description
Access
CONFIGURE
Logging of Raw
Obs
164
With SmartStation it is possible to add the ability to log raw GPS data, which is
then post-processed at the office.
The settings on this screen define the logging of raw observations.
This is a protected option and is only activated by the entry of a license key.
This menu option is licence protected and is only activated by the entry of a
licence key. The licence key can only be loaded from the CompactFlash card.
Select Main Menu: Config...\SmartStation...\Logging of Raw Obs.
Description of fields
Field
Option
<Log Raw Obs:>
Never
Static Only
<Log Rate:>
From 0.05s to
300.0s
<Switch Off:>
Choicelist
Next step
CONT (F1) returns to TPS1200+ Main Menu.
CONT (F1)
Description
Available unless <R-Time Mode: Refer-
ence>. No raw observation logging
during either static or moving intervals.
Available unless <R-Time Mode: Refer-
ence>. Raw observation logging during
static intervals when occupying a point.
Available unless <Log Raw Obs: Never>
or <Log Raw Obs: No>. Rate at which
raw observations are logged.
This option determines when Smart-
Antenna is turned off. The selected time is
activated whenever SmartStation leaves
GPS mode.
This option is directly linked to <Switch
Off:> in CONFIGURE Start Up & Power
Down. Refer to "19.6 Start Up & Power
Down" for details.