Counting
3 Counting
3.1
Note
17
The terminal has additional functions for piece counting. The relevant settings in the
menu are described in Section 4.4.1.
Counting parts into a container
1. Place the empty container on the scale and press
The container is tared and the zero display appears.
2. Place 10 reference parts on the scale and press
-or-
➜ Place the number of pieces displayed above the key
.
The scale determines the average piece weight and then shows the number of
pieces.
3. Add more parts to the container until the required number of pieces is reached.
•
The average piece weight remains saved in the factory setting until a new average
piece weight is determined.
•
With
it is possible to switch between the number of pieces and the weighing
units preset.
•
When the number of pieces is displayed, it is possible to display with
average piece weight, i. e. the weight of a single reference part, for 2 seconds.
•
If A.CL-APW ON is set in the menu, the average piece weight is automatically
cleared after each counting operation. The average piece weight must be deter-
mined again for the next counting operation.
•
If ACCurCY ON is set in the menu, the accuracy achieved is briefly shown after
the number of pieces is determined.
ITS-BA-e-0720
.
.
on the scale and press
User manual ME-Nr.:22017077 01/07
the