Table 5-2 Identification Of Communications Firmware; Table 5-3 Standard Diagnostics - Siemens SINAMICS CU240S DP-F Operating Instructions Manual

Hide thumbs Also See for SINAMICS CU240S DP-F:
Table of Contents

Advertisement

Troubleshooting/FAQs
Identification of the communications components
The read-only parameter r2053 shows the information by which the various firmware
components of the PROFIBUS-DP interface can be identified.
Table 5-2
Parameter
r2053.00
r2053.01
r2053.02
r2053.03
r2053.04
Standard diagnostics
When the parameter P2041.03 = 0, then by using the read-only parameter r2054 and it's
indices, it is possible to obtain detailed diagnostic information regarding the PROFIBUS-DP
interface. This information is listed in table below.
Table 5-3
Parameter
r2054.00
r2054.02
r2054.03
r2054.04
r2054.05
When parameter accessing errors occur, r2054.03 display the appropriate error number,
these are listed in table below.
5-4
Identification of communications firmware
Meaning
0: Inverter cannot identify the communications interface
1: PROFIBUS DP detected
2: No assigned
56: Undefined communications error
Firmware version
Constant "0"
Firmware date (year)
Firmware date (day and month)
Standard diagnostics
Meaning
PROFIBUS-DP status:
0: Off
1: Baud rate search
2: Baud rate found
3: Cyclical data exchange
(> 100: other diagnostic screen active)
Number of acyclical links with class 2 master (PC, OP): 0 ... 2
Error number of last unsuccessful parameter access operation through an acyclical
link.
Parameter number of last unsuccessful parameter access operation
Sub-index of last unsuccessful parameter access operation
Operating Instructions (Compact), 04/2006, A5E00766042B AA