2DC

(3) Removing the power supply board and high voltage board

1. Remove the process unit (See page 1-6-2).
2. Remove the left cover (See page 1-6-4).
3. Remove three connectors from the power supply board.
4. Remove eight screws.
5. Remove the power supply board and high voltage board. (Note: The high voltage board is directly connected to the
bias board.)
6. Separate the high voltage board from the power supply board.
Power supply
Screws
Figure 1-6-14 Removing the power supply board and high voltage board
1-6-12
board
Connectors
Bias board
High voltage
board
Screws