Removing The Power Supply Board And High Voltage Board - Kyocera FS-1020D Service Manual

Hide thumbs Also See for FS-1020D:
Table of Contents

Advertisement

2FM

(3) Removing the power supply board and high voltage board

1. Remove the process unit (See page 1-6-2).
2. Remove the left cover (See page 1-6-4).
3. Remove three connectors from the power supply board.
4. Remove nine screws.
5. Remove the power supply board and high voltage board. (Note: The high voltage board is directly connected to the
bias board.)
6. Separate the high voltage board from the power supply board.
Connectors
Screws
Power supply board
Figure 1-6-13 Removing the power supply board and high voltage board
1-6-12
Screws
Bias board
High voltage board
Screws

Hide quick links: