(5) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is not correct.
U065
(main scanning
direction)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Also, perform "(6) Adjusting magnification of the scanner in the auxiliary scanning direction" (page 1-6-46) and "(8)
Adjusting the scanner center line" (page 1-6-48) after this adjustment.
Procedure
Enter "065" using the copy exposure
adjustment keys or zoom +/- keys.
direction) using the copy exposure
machine enters the test copy mode.
Place an original and press
the start key to make a test copy.
U065
(auxiliary scanning
direction) (P. 1-6-46)
Start
Enter maintenance mode.
Press the start key.
Select "Exp. 1" (main scanning
adjustment keys.
Press the program key and the
Is the image correct?
Yes
Press the stop/clear key to
exit maintenance mode.
End
U067
(P. 1-6-48)
Original
Press the start key.
For copy example 1, increase the
value using the zoom (+) key.
No
For copy example 2, decrease the
value using the zoom (–) key.
Setting range: –25 – +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
Copy
Copy
example 2
example
Figure 1-6-55
The new setting
is stored.
2DC
1-6-45