8. REASSEMBLY
Reverse procedures ro install the burners. Make
sure that the burner is correccly centered on the
orifice. Before replacing all the grates erc., go ro
the next section "Hook Up". Ir is necessary ro
adjust all the air shurrers (excepr the oven broiler)
and the low serring prior ro final assembly, Step
7, Tesr and Adjusrmenr.
9
HOOK UP
A manual valve must be installed external to the
appliance, in an accessible location from the front
for the purpose of shutting off the gas supply. The
supply line must not protrude beyond the back of
the unit. Make sure the gas supply is turned off at
the wall valve before connecting the appliance.
*NOTE- The Arrou' on the Regulator indicatIng
direction of gas flow should be pointing towards the
front of the unit.
**The flex line for the gas supply must be metal
and be approved by an approved certifying
agency (AGA, CGA, or U.L.). Never use a hose
made of rubber or other synthetic material, as the
heat may cause the hose to melt and develop
leaks.
The backguard is installed after the gas connec-
tion is made. The backguard must be installed
when there is less than a 12" clearance betWeen
combustibles and the back of the range (above
the cooking surface:) -See Fig. 3. A stainless steel
trim channel is available for covering the back-
guard mounting flanges for an island installation
-See Fig. 16
The gas supply connections should be made by a
competent technician and in accordance with local
codes or ordinances. In the absence of a local
code, the installation must conform to the
National Fuel Gas Code ANSI 223.1-1988, latest
edition.
.CAUTION:
The appliance must be isolat-
ed from the building s gas supply piping system by
closing its individual manual shut-off valve during
any pressure testing of the gas supply piping ~ystem at
test pressures equal to or less than 1/2 psig
(3.5kPa.). II
FIG. 15:
The appliance and its individual shut-off valve
must be disconnected from the gas supply piping sys-
tem during any pressure
testing of the system at the test pressures in excess of
1/2 psig (3.5kPa.)."
When checking the manifold gas pressure, the inlet
pressure to the regulator should be at least 70" WC.
for natural gas or 12.0"forLP.