External Scsi Port; Physical Specifications; Environmental Requirements; Table 2-6 External Dimensions - Sun Microsystems Fire V250 Installation Manual

Server
Hide thumbs Also See for Fire V250:
Table of Contents

Advertisement

External SCSI Port

The SCSI port is a mulitmode Ultra160 SCSI interface. To operate at Ultra160 SCSI
speeds, it must be in LVD mode. If a single-ended device is connected to the server,
it automatically switches to single-ended mode. (The internal SCSI bus is not
affected.)

Physical Specifications

TABLE 2-6
Height
Width
Depth
Weight

Environmental Requirements

You can operate and store the system safely under the conditions specified in
TABLE 2-7
TABLE 2-7
Specification
Ambient temperature
Relative humidity
Altitude
16
Sun Fire V250 Server Installation Guide • September 2003
External Dimensions
,
and
FIGURE 2-2
FIGURE 2-3
Operating and Storage Specifications
Operating
41˚F to 104˚F (5˚C to 40˚C)
maximum ambient
temperature is derated by 1˚C
per 500m altitude above 500m
10% to 90% RH non-
condensing, 27˚C max wet
bulb
-1,312 feet to 9,842 feet (-400m
to 3000m)
19.16 inches (486.6 mm)
8.65 inches (219.6 mm)
24.16 inches (613.6 mm)
30.8 kg (with maximum number of PSUs and
HDDs installed)
.
Storage
-40˚F to 149˚F (-40˚C to 65˚C)
up to 93% RH non-
condensing, 38˚C max wet
bulb
-1,312 feet to 39,370 feet
(-400m to 12000m)