3.8 PAPER END SENSOR REPLACEMENT

[B]
[A]
1. Paper tray
2. [A] Paper end sensor bracket (! x 1, " x 1)
3. [B] Paper end sensor
NOTE: After replacing the sensor, pull the sensor cable towards the right side of
the frame [C] so that it does not touch the paper in the tray.

3.9 VERTICAL TRANSPORT SENSOR REPLACEMENT

[D]
1. Open the right door [A].
2. [B] Right guide plate (! x 2)
3. [C] Vertical transport sensor bracket (! x 1, " x 1)
4. [D] Vertical transport sensor
SM
PAPER END SENSOR REPLACEMENT
[C]
B384R106.WMF
[C]
[A]
B384R105.WMF
9-17
[B]
B384