Ricoh B039 Service Manual page 154

Gestetner, lanier, ricoh, savin mfp
Table of Contents

Advertisement

4
Mode Number/Name
904
4
ODD result
5
Number of attempts
6*
Factory setting - EVEN
7*
Factory setting - ODD
905
SBU White Level Adjustment
1*
EVEN target
2*
ODD target
3
EVEN result
4
ODD result
5
Number of attempts
6*
Factory setting - EVEN
7*
Factory setting - ODD
906
SBU White Level (EVEN/ODD)
1*
Set value
2
Result
3*
Factory setting
SM
USING SERVICE PROGRAM MODES
Function/[Setting]
Displays the value from the most recent ODD channel
black level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
Displays the number of times SBU black level adjustment
was performed before the target values in 4-904-1 and 2
were reached.
DFU
Displays the value of the black level for the EVEN channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
Displays the value of the black level for the ODD channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
This is the reference value for the EVEN channel white
level used for white level adjustment at power-up.
[0 ~ 255 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
This is the reference value for the ODD channel white
level used for white level adjustment at power-up (set at
the factory).
[0 ~ 255 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
Displays the value from the most recent EVEN channel
white level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
Displays the value from the most recent ODD channel
white level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
Displays the number of times SBU white level adjustment
was performed before the target values in 4-904-1 and 2
were reached.
DFU
Displays the value of the white level for the EVEN channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
Displays the value of the white level for the ODD channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
This is the reference value for the White Level EVEN/ODD
adjustment carried out at power-up.
[0 ~ 600 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
Displays the value from the most recent EVEN/ODD SBU
White Level adjustment.
DFU
Displays the factory-set White Level EVEN/ODD setting.
DFU
5-13