Zones Setup; Unswitched Zones - (Common Zone); Switched Zones; Dgch Installer Setup Parameters (Example) - BONAIRE Installation Instructions Manual

3 & 4 star ducted gas central heater
Hide thumbs Also See for BONAIRE:
Table of Contents

Advertisement

14

Zones Setup

Unswitched Zones- (Common Zone)
The system is capable of operating a common (or unswitched) zone allowing all
other zones to be turned off.
In the unswitched zone parameter, set the parameters required according to HE
parameter table.
1 – Allows all other zones to be switched off
0 – Will not allow all zones to be turned off and one must always be on.

Switched Zones

The system is capable of controlling up to 8 switchable zones. The number of zones
shown in the display is set from parameter 2 in the Ducted Gas Central Heater
Installer Parameter table. The Navigator Controller needs to have parameter 2
changed to 127, this will display all zones on the controller.

DGCH INSTALLER SETUP PARAMETERS (Example)

Single heater- No zone dampers, common zone only
Parameter
Unswitched Zones
Switched Zones
Single Heater - 2 zone dampers
Parameter
Switched Zones
Single Heater - 4 zone dampers
Do nothing. Default controller parameters are set for 4 zones and no common zone.
ADDING ZONES
1. Enter the Installer Navigator Controller set up parameters.
2. Proceed to parameter 2 and press ENTER.
3. Set the value to 127 and press ENTER.
4. Exit this setup by pressing ON/OFF.
5. Enter the Ducted Gas Central Heater Installer parameter setup.
6. Press the ZONE button to toggle on or off the zones you require (indicated by the
S under the zone number).
7. Press the Ï or Ð buttons to move to the next zone.
8. Press the ENTER button to select.
MULTIPLE CONTROLLERS – SHARED ZONES
Single DGCH with individual zones and multiple Navigator controllers
For multiple Navigator controllers, the best results require one Navigator measuring
the temperature in zones 1 & 2, the other measuring zones 3 & 4. None should
measure the common zone. This assumes that the Navigators are physically
installed in Zones 1 and 3 respectively
Id
Value
Meaning
1
1
common zone enabled
2
0
no switched zones
Id
Value
Meaning
2
3
Zones 1 & 2 installed
17
Part 5442225 issue E