Ducted Gas Central Heater (DGCH) Installer Parameter Table

HE Parameter Table ("HE XX")
Parameter
Description
Un switched Zone
Option
1
Switched Zones
2
Cool Enable
3
Room fan speed
4
minimum
Room fan speed
5
maximum
Zone 1 Weight
6
Zone 2 Weight
7
Zone 3 weight
8
Zone 4 Weight
9
Zone 5 Weight
10
Zone 6 Weight
11
Zone 7 Weight
12
Zone 8 Weight
13
Zone Common
14
Weight
15
Not used
0
Not used
Default
Definition
To allow for a
common zone
1
and all zones to
be switched off if
necessary
To display all
available
switched zones
15
Enables the
control board to
drive refrigerated
0
cooling
Low modulated
12
fan speed
Maximum fan
30
speed
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
8
required for zone
Air flow capacity
16
required for zone
0
16
Options Values
1= Allows all zones
to be switched off.
0= Does not allow all
zones to be
switched off
0=No switched
zones.
15= Zone 1, 2,3 & 4
6 = Zone 2&3
127 = 8
Using ZONE and
ÐÏ buttons whilst in
this parameter will
set the number
0=Off – Not driving
Refrig cooling (Dual
Cycle)
1=On – Allowing
Refrig cooling to
operate.
Range 3 - 25
Range 10 - 31
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Range 1 - 16
Part 5442225 issue E