Accessing Ducted Gas Central Heater (Dgch) Installer Setup - BONAIRE Installation Instructions Manual

3 & 4 star ducted gas central heater
Hide thumbs Also See for BONAIRE:
Table of Contents

Advertisement

12

Accessing Ducted Gas Central Heater (DGCH) Installer Setup

NOTE: The Navigator Controller must be in the
OFF status to change the parameters.
(Except Fan Speed)
1. Press and hold the ENTER button for 3 seconds.
2. Press & release the Ï then Ð then SETUP
buttons to enter the installer set up mode.
3. The word "InST", "nSTA", "STAL", "TALL", "ALLE",
"LLEr"(Installer) will scroll across the upper part of
the display. Press the ENTER button now to
access.
4. When the CodE "11 11" appears, input the code
"98 76" using the Ï or Ð buttons to change each
digit, and press the ENTER button to move on to
the next digit.
NOTE: The Navigator Controller will display
the appliance controller ID "HE XX" for
a central heater ("XX" is the unique ID
number).For example "HE 44".
5. Press the ENTER button when "HE XX" appears.
The display will now show digits "1 1". The lower
left digit is the parameter number and the lower
right
digit
Parameter numbers and option values can be
found in the Ducted Gas Central Heater Installer
Parameters Table.
6. To select the parameter number use the Ï or Ð
buttons to find the desired parameter and press
ENTER.
7. Adjust the option value (See DGCH parameter
table) to the required value and press ENTER.
This will set the option value and return you to the
parameter number selection menu.
8. When finished press the ON/OFF button to exit.
is
the
parameter
option
value.
Parameter
Number
15
Options Value
Part 5442225 issue E

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3 & 4 star ducted gas central heater

Table of Contents