Rosslare AYC-W6500 Installation And Operation Manual page 23

Integrated reader and controller
Table of Contents

Advertisement

Changing the Programming Code
The programming code is used to enable programming the reader. The
programming code is set in menu 3.
To Change the Programming Code:
1.
Enter Programming Mode (see Entering Programming Mode, page
17).
2.
Press "3" to enter Menu 3.
3.
Enter the new code you wish to set as the
programming code.
4.
System returns to Normal Access Mode
The unit sounds three beeps.
Note:
Changing the Secure Code
The Secure Code is used to switch from Normal Mode to Secure Access
Mode. The Secure Code is set in Menu 4.
To Change the Secure Code:
1.
Enter Programming Mode (see Entering Programming Mode, page
17).
2.
Press "4" to enter Menu 4.
3.
Enter the new code you wish to set as the
Secure Code.
4.
System returns to Normal Access mode.
The unit sounds three beeps.
The default Secure code is 3838.
This code can be erased by entering the PIN code value 0000.
Changing the Facility Code
This code is used only by PIN codes that are transmitted in multiple keys
formats. It is inserted in the MSB byte of the transmitted data, one bit
following the leading parity bit.
AYC-W6500 Installation Manual
The programming code cannot be erased. The
code 0000 is not valid and does not delete the
programming code.
The factory default programming code is 1234.
It is recommended to change the default
programming code.
Note:
Reader Functionality
.