Turn Rate Limit; Off Course Angle - Raymarine SmartPilot X5 Installation & Setup Manual

Tiller & gp tiller
Hide thumbs Also See for SmartPilot X5:
Table of Contents

Advertisement

Chapter 4: SPX-5 Tiller system settings
Screen Text
RESPONSE

Turn rate limit

This limits your boat's rate of turn under SPX-5 Tiller system control.
Screen Text
TURN RATE

Off course angle

This screen determines the angle used by the
Operating Guide ). The
more than the specified angle for more than 20 seconds.
Screen Text
OFF COURSE
Options
Range = 1 to 9
Level 1 to 3 minimizes the amount of pilot activity. This conserves
power, but may compromise short-term course-keeping accuracy
Level 4 to 6 should give good course keeping with crisp, well con-
trolled turns under normal operating conditions
Level 7 to 9 gives the tightest course keeping and greatest rudder
activity (and power consumption). This can lead to a rough passage
in open waters as the SPX-5 Tiller system may 'fight' the sea.
Range
1° to 30° per second in 1° steps
OFF COURSE
alarm operates if the pilot strays off course by
Range
15° to 40° in 1° steps
Locked heading
15˚ minimum
OFF COURSE
alarm (see your
Boat heading
55