40
Boat completes AutoLearn
!
If you need to cancel the AutoLearn, press
Save new settings

Commissioning complete

Your SPX-5 Tiller system is now commissioned and ready for use.
After having used your SPX-5 Tiller system, you may decide to change the value of
some parameters to improve pilot performance with your boat. If you feel this is
necessary, use the appropriate procedures under Manual setup , below.

3.2 Manual setup

Checking SPX-5 Tiller system operation

Before manually adjusting any of these settings, familiarize yourself with basic SPX-5
Tiller system operation, as follows:
1. Steer onto a compass heading and hold the course steady at a normal cruising
speed. If necessary, steer the boat manually for a short time to check how the boat
steers.
2. Press auto to lock onto the current heading. The SPX-5 Tiller system should hold
the locked heading in calm sea conditions.
3. Use -1, +1, -10 and +10 and observe how the SPX-5 Tiller system alters the
course to port and starboard.
4. Press standby to return to manual steering.
If you feel you need to fine tune the SPX-5 Tiller system performance, you can do so
by using one or more of the procedures below to adjust:
Response level.
Rudder gain.
Counter rudder.
AutoTrim.
SmartPilot X-5 Tiller & GP Tiller Installation & Setup Guide
AutoLearn successful
After
7 to 27
steps
2 sec
Note: If you see a
LRN FAIL message,
press disp to return to
the AUTOLEARN screen
then repeat from Step 2
or
To:
• save AutoLearn calibration settings
• return to STANDBY mode
D10546-1