Connection procedure

Distribution
panel
Fuse or
circuit
breaker
At the Course Computer, locate the free ends of the power cable from the distribution
panel and Tiller Drive cable. Ensuring all power is switched off, refer to the following
illustration and connect each cable to the correct Course Computer terminals as
follows:
1. Strip 8-10 mm (1/2 inch) of insulation from the end of each wire.
2. Use a small screwdriver to loosen the relevant screws on the terminal block.
3. Insert the stripped wires into the appropriate terminals and tighten the screw.
SmartPilot X-5 Tiller & GP Tiller Installation & Setup Guide
Red
Black
Power supply
A
B
Brown
Blue
Drive unit
D10622-1