Generator Connection (RV Series only)
Proper installation and setup of the ac generator is essential for the correct
operation of the inverter/charger. The RC7GS contains the proper software code
to work with various generators listed in the LCD display.
NOTE: The RV Series inverter/charger must be at Software Rev. 1.3x to
interface correctly with the RC7GS.
Connect the generator to the inverter as shown in the following diagrams.
Select the generator type and model, as previously described under "Select
Genset" on page 15.
NOTE: The terminal strip for connecting the generator is shown below. Refer to
the RV Series inverter/charger Operator's manual for complete wiring details.
Genset Connections on RV Series Inverter/Charger Terminal Strip
1.
Onan Quiet Diesel - HDKAJ, HDKAK, 7.5/8/10 and 12.5 kw
Connect the generator as shown below.
1 999 Trace Engineering
ã
RC7 & RC7GS Remote Controls
Figure 67
COM. GEN START 1
N.O. GEN START 2
START
N.C. GEN RUN 3
COM. GENRUN 1
GROUND
N.O. GEN RUN 2
STOP
INVERTER/CHARGER
Figure 68
Onan Quiet Diesel Connections
E
5 A
C
A
GENSET
5 A
CONNECTOR
822-4A-008
3.0 OPERATION