Set Shore Power
The inverter monitors the ac power being drawn by both the battery charger
and the ac loads connected to the inverter. If the current draw approaches the
shore power circuit breaker rating, the battery charger reduces the amount of
current supplied to the batteries to provide the maximum current to the ac loads.
Set Shore Power ensures the battery charger does not exceed the shore power
circuit breaker rating. This setting should match the shore power or generator's
circuit breaker rating. The default setting is 30 amps.
Set Shore Power
30 Amps
7.
RC7 Setup
The RC7 LCD screen displays system status and error messages that occur
during normal operation. From the Setup menu select:
Last Key (default) to display the last system status message displayed after
exiting the Setup menu.
Rolling Display to automatically show system status, state-of-charge, time
left to run, time left to charge, set shore power and gen start/stop (RC7GS only).
Power Saver to shut off the LCD display and LEDs after five minutes
without a key-press or new error message. Pressing any key will reactivate the
LCD display and LEDs for another five minutes. Errors during the power saver
mode will "wake-up" the remote.
12
Set Shore Power
Set Shore Power
25 Amps
20 Amps
Set Shore Power Selections
RC7 Setup:
Last Key
Set Shore Power Selections
Set Shore Power
Set Shore Power
15 Amps
10 Amps
Figure 18
RC7 Setup:
RC7 Setup:
Rolling Display
Power Saver
Figure 19
Set Shore Power
5 Amps
1 999 Trace Engineering
ã
Need help?
Do you have a question about the RC7 and is the answer not in the manual?
Questions and answers