Begin Gen Quiet and End Gen Quiet

The period of time during which the generator is prevented from starting
automatically can be defined using the RC7GS.
To specify the begin quiet time, scroll to the Begin Gen Quiet: 00:00
by using the UP and DOWN arrow push-buttons. Set the Begin Gen Quiet start
time. The selected digit for hours or minutes will be underlined and highlighted
(refer to the Set Clock section for details on setting the time).
Press the DOWN arrow to access the End Gen Quiet: 00:00 menu and
select the appropriate end time.
NOTE: Setting begin and end time to 00:00 defeats the quiet time mode.
NOTE: If the generator is running at the begin quiet time, it will be shut down
automatically. If the auto-start parameters are met during quiet time, the buzzer
will sound and the LCD displays the message "Gen Quiet Fault." The generator
will start automatically at the end of the quiet time.
1 999 Trace Engineering
ã
RC7 & RC7GS Remote Controls
Begin Gen Quiet
00:00
Figure 30
Start Generator Quiet Time
End Gen Quiet
00:00
Figure 31
End Generator Quiet Time