Specifications; General Description - Panasonic Pure IP-PBX KX-TDE600 Installation Manual

Pure ip-pbx
Hide thumbs Also See for Pure IP-PBX KX-TDE600:
Table of Contents

Advertisement

1.3 Specifications

1.3.1 General Description

Control Bus
Communication Bus
Switching
Power Input
Maximum Power Failure Tolerance
Power
Consumption (per
shelf)
Memory Backup Duration
Dialing
Mode Conversion
Ring Frequency
Central Office Loop Limit
Operating
Environment
Conference Call CO Line (per shelf)
Music on Hold (MOH)
Paging
Serial Interface
Port
RJ45 Port
Extension Connection Cable
Document Version 2009-12
Original bus (16-bit, 8 MHz, 10 megabytes per second)
H.100 bus conformity (1024 time slots)
Distributed Switching
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50
Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A;
50 Hz/60 Hz
300 ms
*1
With PSU-M
190 W; 2.5 A (at 120 V AC; 60 Hz)
With PSU-L
410 W; 5.1 A (at 120 V AC; 60 Hz)
7 years
CO Line
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 W maximum
Temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10 % to 90 % (non-condensing)
From 10 ´ 3-party conference call to 4 ´ 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (maximum 115.2 kbps)
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
SLT
DPT
APT
1.3.1 General Description
1-pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
Installation Manual