Specifications; General Description; Characteristics - Panasonic KX-TDE200GR Service Manual

Pure ip-pbx
Hide thumbs Also See for KX-TDE200GR:
Table of Contents

Advertisement

3 Specifications

3.1.

General Description

Control Bus
Communication Bus
Switching
Power Input
External Battery
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface Port
LAN I/F
Extension Connection Cable
Dimension
Weight (when fully mounted)
3.2.

Characteristics

Terminal Equipment Loop Limit
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Trunk Loop Limit
Hookswitch Flash/Recall Timing Range
BRI Cards Internal ISDN Mode
Door Opener Current Limit
External Relay Current Limit
External Sensor Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal Impedance
Original bus (16 bit, 8 MHz,10 megabytes per second)
H.100 bus conformity (1024 time slot)
Non Blocking
PSU-S
100 V AC to 130 V AC; 1.4 A/200 V AC to 240 V AC; 0.8 A; 50 Hz/60 Hz
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50 Hz/60 Hz
+36 V DC (+12 V DC x 3, recommended maximum capacity is 28 Ah)
300 ms (without using backup batteries)
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 Ω maximum
0 °C to 40 °C
Temperature
Humidity
10%to 90% (non condensing)
From 10 x 3-party conference call to 4 x 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (max 115.2 kbps)
RJ45
2 (10BASE-T/100BASE-TX)
SLT
DPT
APT
PT-interface CS
DSS Consoles and Add-on Key Module
KX-TDE200NE
430 mm (W) x415 mm (H) x 276 mm (D)
(17 1/5 in x 16 3/5 in x 10 7/8 in)
KX-TDE200NE
Under 16 kg (35.2 lb)
• PT: KX-T7600 series DPT: 90 Ω; all other DPTs/APTs: 40Ω
• SLT: 600 Ω including set
• Doorphone: 20 Ω
• . CS: 130Ω; PT-interface CS: 65Ω
15000 Ω maximum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600 Ω maximum
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
24 V DC/30 V AC, 1 A maximum
24 V DC/30 V AC, 1 A maximum
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100Ω.
600 Ω
10000 Ω
1 pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
1-pair wire (D1, D2)
1-pair wire (D1, D2)
5
KX-TDE200GR

Advertisement

Table of Contents
loading

Table of Contents