3 Specifications

3.1.

General Description

Control Bus
Communication Bus
Switching
Power Input
Maximum Power Failure Tolerance*1
Power Consumption (per shelf)
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Central Office Loop Limit
Operating Environment
Conference Call CO Line (per shelf)
Music on Hold (MOH)
Paging
Serial Interface Port
RJ45 Port
Extension Connection Cable
Dimension
Weight (when fully mounted)
*1 If tolerance may be exceeded, an Uninterruptible Power Supply (UPS) is recommended.
3.2.

Characteristics

Terminal Equipment Loop Limit
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Central Office Loop Limit
Hookswitch Flash Timing Range
Door Opener Current Limit
External Relay Current Limit
External Sensor Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal Impedance
Original bus (16 bit, 8 MHz,10 megabytes per second)
H.100 bus conformity (1024 time slot)
Distributed Switching
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A; 50 Hz/60 Hz
300 ms
With PSU-M
190 W; 2.5 A (at 120 V AC; 60 Hz)
With PSU-L
410 W; 5.1 A (at 120 V AC; 60 Hz)
7 years
CO Line
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 Ω maximum
Temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10%to 90% (non condensing)
From 10 x 3-party conference call to 3 x 8-party conference call
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
RS-232C
1 (max 115.2 kbps)
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
SLT
DPT
APT
PT-interface CS
PT-interface CS (High-density)
DSS Consoles and Add-on Key Module
430 mm (W) x 415 mm (H) x 270 mm (D)
(17-1/5 in x 16-3/5 in x 10-4/5 in)
Under 16 kg (35.2 lb.)
• PT: KX-DT300/KX-T7600 series DPT: 90 Ω; all other DPTs/APTs:40 Ω
• SLT: 600 Ω including set
• Doorphone: 20 Ω
• CS: 130 Ω; PT-interface CS: 65Ω
15000 Ω maximum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600 Ω maximum
24 ms to 2032 ms
24 V DC/30 V AC, 1 A maximum
24 V DC/30 V AC, 1 A maximum
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100Ω.
600 Ω
10000 Ω
1 pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
1-pair wire (D1, D2)
4-pair wire (D1, D2)
1-pair wire (D1, D2)
6